MXC150050B-MG is a 50 kW, 1500 V bidirectional DC‑DC microgrid module with hot‑plug simplicity, dual‑side auxiliary power, and precise voltage/current tuning (0.1 V/0.1 A). It features fast, safe switching backed by under-/over‑voltage, over‑temperature (–20 ℃~75 ℃), and communication interruption protection. Its high efficiency and rugged design suit battery storage, renewable integration, and V2G applications in demanding microgrid environments.
A Side Voltage VS A Side Current curve
B Side voltage VS B Side current curve
Power VS Ambient temperature derating curve
| Product Model | MXC150050B-MG | |
| A Side | Voltage Range | 1000~1500Vdc |
| Max Current | 47.5A | |
| Stabilized Voltage Precision | ≤±0.5% | |
| Stabilized Current Precision | ≤±1% (A side load 20%~100% rated current) | |
| Current Sharing Imbalance | ≤5% | |
| B Side | Output Power | 50kW |
| Voltage Range | 200-920Vdc | |
| Max Current | 112A | |
| Stabilized Voltage Precision | ≤±0.5% | |
| Stabilized Current Precision | ≤±1% (B side load 20%~100% rated current) | |
| Ripple Peak Value | ≤1% | |
| Current Sharing Imbalance | ≤5% | |
| Environmental Specifications | Operating Temperatue | -20℃~+75℃,Above 50℃will be derated. |
| Altitude | ≤2000m,Above 2000m will be derated. | |
| Basic Specifications | Size(W×D×H) | 345×460×87mm |
| Weight | <17.5kg | |
| Efficiency(full load) | >98.5% | |
| Isolated Method | High Frequency Isolated | |
| Cooling Mode | Air cooling | |
| Protection level | IP20 | |
| Communication Method | 1 CAN bus, 1 RS485 (optional protocol conversion module, support Modbus TCP) | |
| Parallel Module Quantity | ≤60pcs | |
| Hardware stop driver | With 12V enable signal (low level to operate, high level to shut down) | |